dot
Detailansicht
Katalogkarte GBA
Katalogkarte ISBD
Suche präzisieren
Drucken
Download RIS
Hier klicken, um den Treffer aus der Auswahl zu entfernen
Titel Effects of column density on I2 spectroscopy and a determination of I2 absorption cross section at 500 nm
VerfasserIn P. Spietz, J. Gómez Martín, J. P. Burrows
Medientyp Artikel
Sprache Englisch
ISSN 1680-7316
Digitales Dokument URL
Erschienen In: Atmospheric Chemistry and Physics ; 6, no. 8 ; Nr. 6, no. 8 (2006-06-20), S.2177-2191
Datensatznummer 250003926
Publikation (Nr.) Volltext-Dokument vorhandencopernicus.org/acp-6-2177-2006.pdf
 
Zusammenfassung
The use of ro-vibronic spectra of I2 in the region of 543 nm to 578 nm as reference spectra for atmospheric Differential Optical Absorption Spectroscopy is studied. It is shown that the retrieval of atmospheric column densities with Differential Optical Absorption Spectroscopy set-ups at FWHM at and above 1 nm depends critically on the column density, under which the used reference spectrum was recorded. Systematic overestimation of the comparatively low atmospheric column density of I2 of the order of 13% is possible. Under low pressure conditions relevant in laboratory studies, the systematic deviations may grow up to 45%. To avoid such effects with respect to field measurements, new reference spectra of I2 were determined under column density of the order of 1016 cm-2 close to that expected for an atmospheric measurement. Two typical configurations of Differential Optical Absorption Spectroscopy, which use grating spectrometers, were chosen for the spectroscopic set-up. One spectrum was recorded at similar resolution (0.25 nm FWHM) but finer binning (0.035 nm/pixel) than previously published data. For the other (0.59 nm FWHM, 0.154 nm/pixel) no previously published spectra exist. Wavelength calibration is accurate to ±0.04\,nm and ±0.11 nm respectively. The absorption cross section for the recordings was determined under low column density with an accuracy of ±4% and ±3% respectively. The absolute absorption cross section of I2 at 500 nm (wavelength: in standard air) in the continuum absorption region was determined using a method independent of iodine vapour pressure. Obtained was σI2 (500 nm)=(2.186±0.021·10-18 cm2 in very good agreement with previously published results, but at 50% smaller uncertainty. From this and previously published results a weighted average of σI2(500 nm)=(2.191±0.02)·10-18 cm2 is determined.
 
Teil von