Zusammenfassung |
Highly contaminated zone with a maximum over 57,000 Bq/m3 was discovered in low-populated area "Agua de Venados" during the 2009-2011 soil Radon survey in San Joaquin, Querétaro state, Mexico. Indoor Radon monitoring accomplished in 2 different époques in a nearby 4 dwellings have shown increased Radon contamination in 1 of the 4 building (up to 300 Bq/m3) during a raining season and a highly elevated indoor level (over 400 Bq/m3) already in 3 buildings during a dry season. Averaged diurnal indoor Radon variations are in a correlation with atmosphere pressure and air humidity and are independent on air temperature. The daily interval 5-10 a.m. was estimated as a maximum risky period in terms of Radon contamination hazard for inhabitants in mentioned zone. |
|
|
|
|
|