dot
Detailansicht
Katalogkarte GBA
Katalogkarte ISBD
Suche präzisieren
Drucken
Download RIS
Hier klicken, um den Treffer aus der Auswahl zu entfernen
Titel Design and Operation of Large Field Precision Weighing Lysimeters under Snow Conditions
VerfasserIn G. von Unold, A. Steins, J. Fank, W. Durner
Konferenz EGU General Assembly 2009
Medientyp Artikel
Sprache Englisch
Digitales Dokument PDF
Erschienen In: GRA - Volume 11 (2009)
Datensatznummer 250020897
 
Zusammenfassung
The management of water resources requires an accurate evaluation of water fluxes in atmosphere, soils and groundwater. Precision weighing lysimeters with controlled suction at their bottom are recognized to be the best possible measuring instruments to quantify the soil water dynamics, especially the interfaces soil/atmosphere and soil/groundwater under conditions of predominantly one-dimensional water flow in soils. The operation of lysimeters in winter time with snowfall and freezing, however, poses still a major problem. Load force interference from the surrounding area onto the lysimeter, transmitted by the snow cover, can cause big measurement errors. In this presentation we discuss this problem and propose technical solution strategies to handle the problem in order to get unbiased data. We present suitable technical modifications of lysimeters that enable them to for precision water budget calculations also under snow conditions. This is of particular importance for lysimeters that are used in alpine environments.