| Titel |
Evaluation of positioning and density profiling accuracy of muon radiography by utilizing a 15-ton steel block |
| VerfasserIn |
H. K. M. Tanaka |
| Medientyp |
Artikel
|
| Sprache |
Englisch
|
| ISSN |
2193-0856
|
| Digitales Dokument |
URL |
| Erschienen |
In: Geoscientific Instrumentation, Methods and Data Systems ; 2, no. 1 ; Nr. 2, no. 1 (2013-02-18), S.79-83 |
| Datensatznummer |
250017341
|
| Publikation (Nr.) |
copernicus.org/gi-2-79-2013.pdf |
|
|
|
|
|
| Zusammenfassung |
| A model experiment was performed in order to evaluate the spatial resolution
and the accuracy of determining the density by utilizing a steel block. The
steel block (7.8 g cm−3) is 5 m thick along the muon trajectories and
weighs about 15 t. By comparing the experimental result with simulations,
the density and the width of the steel block were measured as
7.3 ± 1.0 g cm−3 and 37 ± 15 cm, respectively. |
| |
|
| Teil von |
|
|
|
|
|
|
|
|