![Hier klicken, um den Treffer aus der Auswahl zu entfernen](images/unchecked.gif) |
Titel |
Indication of short-period (infrasonic) fluctuations in high-resolution OH-airglow data |
VerfasserIn |
C. Pilger, C Schmidt, M. Bittner |
Konferenz |
EGU General Assembly 2009
|
Medientyp |
Artikel
|
Sprache |
Englisch
|
Digitales Dokument |
PDF |
Erschienen |
In: GRA - Volume 11 (2009) |
Datensatznummer |
250024483
|
|
|
|
Zusammenfassung |
OH-airglow measurements with the GRIPS-instruments (GRound-based Infrared P-branch Spectrometer) were performed during the winter 2008/2009 at the German Environmental Research Station “Schneefernerhaus”, Zugspitze (47.4° N, 11° E). Wave activity on multiple scales has been observed and for some events the temporal resolution was sufficient to detect short-period signals below one minute (0.017 – 0.067 Hz). This activity is situated in the far infrasound frequency regime and might be due to a variety of acoustic sources, most likely mountain-associated waves in the Alpine region.
Mesopause temperature time series derived from these OH-airglow measurements with high temporal resolution are presented. The main analysing method used is the wavelet analysis being a powerful tool for the detection and discrimination of transient signals in time series. The possibility to locate a signal in time and frequency space simultaneously is essential for pattern recognition and is described.
First results indicating the possible influence of infrasound on OH-airglow temperatures are presented. |
|
|
|
|
|